Error/Warning Indications; Error Indications; Warning Indications - Sony PXW-X180 Operating Manual

Solid-state memory camcorder
Hide thumbs Also See for PXW-X180:
Table of Contents

Advertisement

Error/Warning Indications

The camcorder informs you of situations where warning, caution, or an operation check is required,
through messages on the viewfinder screen, the recording/tally lamp, and a buzzer.
The buzzer is output to the built-in speaker or to the headphones connected via the headphone connector.

Error Indications

The camcorder stops operation after the following indications.
Error indication on
Buzzer
LCD/viewfinder
E + Error code
Continuous

Warning Indications

When one of the following indications is generated, follow the message to resolve the problem.
Warning indication
Buzzer
on LCD/viewfinder
Media Near Full
Intermittent
Media Full
Continuous
Battery Near End
Intermittent
Battery End
Continuous
Temperature High
Intermittent
Voltage Low
Intermittent
Insufficient Voltage
Continuous
Recording/
Cause and measures
tally lamp
Rapidly
The camcorder may be defective. Recording stops even if
flashing
zRec is displayed on the viewfinder screen.
Turn off the power and check the connected equipment, cables,
and media. If they are not defective, turn on the power again. If
the error persists, consult Sony service personnel.
(If power cannot be turned off by setting the ON/STANDBY
switch to STANDBY, remove the battery pack and/or the DC
IN source.)
Recording/
Cause and measures
tally lamp
Flashing
Free space on the SxS memory card has become insufficient.
Replace it with another at the earliest opportunity.
Rapidly
No space is left on the SxS memory card. Recording, clip
flashing
copying and clip division cannot be performed.
Replace it with another.
Flashing
The battery power will be discharged soon.
Charge the battery pack at the earliest opportunity.
Rapidly
The battery pack is discharged. Recording cannot be
flashing
performed.
Stop operation and change the battery pack.
Flashing
The internal temperature has risen above a safe operation
limit.
Suspend operation, turn off the power, and wait until the
temperature falls.
Flashing
The DC IN voltage has become low (stage 1).
Check the power supply.
Rapidly
The DC IN voltage is too low (stage 2). Recording cannot be
flashing
performed.
Connect another power source.
Error/Warning Indications
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pxw-x160

Table of Contents