Built-in Outputs
Relationship between the
Coordinate System and
Pulse Specification
Coordinate
system
Path specification
made with
instruction
(A28005) or Pulse Output 1 Origin Established
(PULS(886) or
PLS2(887)
Relative pulse speci-
Positions the system to another position relative to the current position.
fication
Number of movement pulses = number of pulses setting
The pulse output PV after instruction execution =
Number of movement pulses = Number of pulses
setting
Note The pulse output PV is reset to 0 just before
The following example shows the number of
pulses setting = −100.
Pulse output PV range:
80000000 to 7FFFFFFF hex
Number of pulses setting range:
00000000 to 7FFFFFFF hex
106
The following table shows the pulse output operation for the four possible
combinations of the coordinate systems (absolute or relative) and the pulse
specifications (absolute or relative) made when PULS(886) or PLS2(887) is
executed.
Relative coordinate system
Origin not established:
The Pulse Output 0 Origin Established Flag
Flag (A28105) will be ON.
pulses are output. After that, the specified number
of pulses is output.
Number of pulses
setting
II
Number of
movement pulses
−100
Pulse
output PV
Target
Current
position
position
Absolute coordinate system
Origin established:
The Pulse Output 0 Origin Established Flag
(A28005) or Pulse Output 1 No-origin Flag
(A28105) will be OFF.
The pulse output PV after instruction execution =
PV + Number of movement pulses.
The following example shows the number of
pulses setting = −100.
Number of pulses
setting
II
Number of
movement pulses
−100
0
Target
Current
Origin
position
position
Pulse output PV range:
80000000 to 7FFFFFFF hex
Number of pulses setting range:
00000000 to 7FFFFFFF hex
Section 5-2
Pulse
output PV