Omron CJ-Series Operation Manual page 121

Built-in i/o. cpu units
Hide thumbs Also See for CJ-Series:
Table of Contents

Advertisement

Built-in Outputs
Operation
Example applica-
tion
Stop pulse
Immediate stop
output
(Number of
pulses set-
ting is not
preserved.)
Stop pulse
Immediate stop
output
(Number of
pulses set-
ting is not
preserved.)
Stop pulse
Decelerate to a
output
stop
smoothly.
(Number of
pulses set-
ting is not
preserved.)
102
Stopping a Pulse Output
Frequency changes
Pulse frequency
Present
frequency
Execution of
SPED(885)
Pulse frequency
Present frequency
Execution of
SPED(885)
Pulse frequency
Present
frequency
Target
frequency = 0
Execution of
ACC(888)
Description
Stops the pulse out-
put immediately
and clears the num-
ber of output pulses
setting.
Time
Execution
of INI(880)
Stops the pulse out-
put immediately
and clears the num-
ber of output pulses
setting.
Time
Execution of
SPED(885)
Decelerates the
pulse output to a
stop.
Original
Note If ACC(888)
deceleration
started the
rate
operation, the
original accel-
Time
eration/decel-
eration rate
will remain in
effect.
If SPED(885)
started the
operation, the
acceleration/
deceleration
rate will be
invalid and
the pulse out-
put will stop
immediately.
Section 5-2
Procedure
Instruction
Settings
PULS(886)
•Stop
pulse out-
put
ACC(888) or
SPED(885)
(Indepen-
dent)
INI(880)
PLS2(887)
INI(880)
PULS(886)
•Port
•Indepen-
dent
SPED(885)
(Indepen-
•Target fre-
dent)
quency =
0
SPED(885)
PULS(886)
•Port
•Indepen-
dent
ACC(888) or
•Target fre-
SPED(885)
quency =
(Indepen-
dent)
0
ACC(888)
(Indepen-
dent)
PLS2(887)
ACC(888)
(Indepen-
dent)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1m-cpu22Cj1m-cpu23

Table of Contents