Check Main Fan Operation (Function Code: 78) - Brother HL-L5000D Service Manual

Hide thumbs Also See for HL-L5000D:
Table of Contents

Advertisement

1.3.19 Check main fan operation (function code: 78)

<Function>
This function is used to check that the main fan is operating normally. Switch the setting
among rotation speed 100%, 50%, and OFF.
LCD
F
<Operating Procedure>
Non touch panel models
(1) Press the [▲] or [▼] key in the initial
state of maintenance mode to display
"MAINTENANCE 78" on the LCD, and
press the [OK] key. "F100" is
displayed on the LCD and the main
fan rotates at 100% speed.
(2) By pressing the [Go] key, "F50" is
displayed on the LCD and the main
fan rotates at 50% speed.
(3) By pressing the [Go] key again, "F 0"
is displayed on the LCD and the main
fan stops.
(4) Press the [X] key, and the machine
returns to the initial state of
maintenance mode.
Name
Main fan
Description
Emits the heat in the fuser unit.
Touch panel models
(1) Press the [7], and then the [8] key in
the initial state of maintenance mode.
"F100" is displayed on the LCD and
the main fan rotates at 100% speed.
(2) By pressing the [Mono] key, "F50" is
displayed on the LCD and the main
fan rotates at 50% speed.
(3) By pressing the [Mono] key, "F 0" is
displayed on the LCD and the main
fan stops.
(4) When you press the [X] key, this
operation is finished and the machine
returns to the initial state of
maintenance mode.