9.10.3 NFC PCB ASSY
(1) Release the NFC flat cable from the securing fixtures.
(2) Release the two hooks, and remove the NFC PCB ASSY from the top cover printed
ASSY.
Top cover printed ASSY
Harness routing: Refer to
Assembling Note:
• Fold the NFC flat cable at the positions shown in the figure below.
Mountain fold
Valley fold
NFC
PCB
side
Conductor
NFC PCB ASSY
NFC flat cable
Hooks
Fig. 3-37
"4. Bottom side of the top cover ASSY (Touch panel
45°±2°
45°±2°
45°±2°
Fig. 3-38
127.5±2
140.5±2
198±2
213±2
3-53
models)".
42.5±2
31.6±2
12.6±2
Panel PCB
45°±2°
side
Conductor
Confidential