7.
Start­up
Observe the instructions in section 3, "Safety instructions"!
The gear unit must not be started up, if the required instructions are not available.
7.1
Procedure before start­up
7.1.1

Removal of preservative agent

Before re­starting the gear unit the screw plug (if fitted) must be replaced with the
breather screw or the air filter.
The location of the oil­draining points is marked by an appropriate symbol in the dimensioned drawing in
the gear­unit documentation.
Oil­draining point:
Place suitable containers under the oil­draining points.
Unscrew the oil­drain plug or open the oil­drain cock.
Remove remaining preservative agent and/or running­in oil from the gear unit using a suitable
container, unscrew any existing residual­oil drain plugs, to do so.
Dispose of remaining preservative agent and/or running­in oil in accordance with regulations.
Remove any oil spillage immediately with an oil­binding agent.
The oil must not come into contact with the skin (e.g. the operator s hands).
The safety notes on the data sheets for the oil used must be observed here!
Screw in oil­drain plug or reclose oil­drain cock.
Screw in any unscrewed residual­oil­drain plugs again.
Fig. 56: Oil inlet / oil drain on gear units type B...
3
1
Fig. 57: Oil inlet / oil drain on gear units types B..H
1
B..H
13
BA 5033 EN 03/2011
73 / 96
3
2
5
4
12
3
5
1
2
4
B..M
13 and B..M
13
5
2
4
13

Hide quick links:

Advertisement

Table of Contents
loading