7.
Startup
Observe the instructions in section 3, "Safety instructions"!
The gear unit must not be started up, if the required instructions are not available.
7.1
Procedure before startup
7.1.1
Removal of preservative agent
Before restarting the gear unit the screw plug (if fitted) must be replaced with the
breather screw or the air filter.
The location of the oildraining points is marked by an appropriate symbol in the dimensioned drawing in
the gearunit documentation.
Oildraining point:
Place suitable containers under the oildraining points.
Unscrew the oildrain plug or open the oildrain cock.
Remove remaining preservative agent and/or runningin oil from the gear unit using a suitable
container, unscrew any existing residualoil drain plugs, to do so.
Dispose of remaining preservative agent and/or runningin oil in accordance with regulations.
Remove any oil spillage immediately with an oilbinding agent.
The oil must not come into contact with the skin (e.g. the operator s hands).
The safety notes on the data sheets for the oil used must be observed here!
Screw in oildrain plug or reclose oildrain cock.
Screw in any unscrewed residualoildrain plugs again.
Fig. 56: Oil inlet / oil drain on gear units type B...
3
1
Fig. 57: Oil inlet / oil drain on gear units types B..H
1
B..H
13
BA 5033 EN 03/2011
73 / 96
3
2
5
4
12
3
5
1
2
4
B..M
13 and B..M
13
5
2
4
13