Table 14: Recommended lubricants for shrink disks after their cleaning
Molykote G Rapid
Aemasol MO 19 P
1)
Other lubricants may be used if they have the same characteristics.
Join inner ring (3) and outer ring (4).
Place the tensioning bolts and screw in some threads by your fingers.
Observe the manufacturer s instructions for handling lubricants!
Fitting and start­up must be carried out by properly trained specialist personnel.
6.7.4
Re­mounting the shrink disk
For re­fitting the shrink disk the procedure described in item 6.7.1 must be adhered to.
6.7.5

Inspection of the shrink disk

In all cases the inspection relating to the shrink disk should be carried out simultaneously with
the examination of the gear unit, however at least every 12 months.
Inspection of the shrink disk is limited to a visual assessment of its condition. The following must be
observed when carrying out this work:
loose screws
damage caused by force
flush position of the inner ring (3) in relation to outer ring (4).
Lubricant
Unimoly P 5
gleitmo 100
BA 5033 EN 03/2011
Form
Spray or paste
Spray or paste
Powder
Spray or paste
65 / 96
1)
Manufacturer
DOW Corning
A. C. Matthes
Klüber Lubrication
Fuchs Lubritec