5.15
Bearingmonitoring system
5.15.1 Bearing monitoring by Pt 100 resistance thermometer
The gear unit may be fitted with Pt 100 resistance thermometers for monitoring the
bearings. In order to measure the temperatures and/or temperature differences, the
Pt 100 resistance thermometer, which should comply with the requirements of
Directive 94/9/EC, must be connected to a suitable evaluating instrument provided by
the customer. The resistance thermometer has a connection head for the wiring.
A twoconductor circuit is provided by the manufacturer. However, the customer may
also fit a three or fourconductor circuit.
For control information, refer to the list of equipment.
Fig. 28: Bearing monitoring by Pt 100 resistance thermometer on gear units type B3.H
For a detailed illustration of the gear unit and the position of the addon parts, please refer to the drawings
of the gearunit documentation.
When operating and servicing the components, observe the operating instructions relating to
the components.
For technical data, refer to the data sheet and/or the list of equipment.
5.15.2 Bearing monitoring by shockpulse transducer
The gear unit may be fitted with measuring nipples for monitoring the bearings. These nipples are intended
for attachment of shockpulse sensors with rapidaction coupling and are located in the vicinity of the
bearings to be monitored.
Fig. 29: Bearing monitoring by shockpulse transducer on gear units type B3.H
For a detailed illustration of the gear unit and the position of the addon parts, please refer to the drawings
of the gearunit documentation.
X
B...
BA 5033 EN 03/2011
40 / 96
"X"
SW17
Measuring nipple