Siemens RUGGEDCOM RST2228 Installation Manual page 49

Table of Contents

Advertisement

RUGGEDCOM RST2228
Installation Guide
Test
IEC 60068-2-14
IEC 60068-2-30
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-3
IEC 60529
IEC 60068-2-31
EMC and Environmental Type Tests
Description
Change of Temperature
Humidity (Damp
Heat, Cyclic)
Humidity (Damp
Heat, Steady State)
Vibration
Shock
Bump
Seismic
Ingress Protection
Free Fall
Test Levels
Test Nb
5 Cycles, -40 to 85°
C (40 to 185° F)
Test Db
93% upper temperature,
97% lower temperature
55 °C (131 °F), 6 Cycles
Test Cab
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
Level 2 (2 g @ 10 to 150 Hz)
Level 2 (30 g @ 11 mS)
Level 1 (10 g @ 16 mS)
Method A, Class 2
IP4x
Test Ec
25 cm
Chapter 6
Certification
Severity Levels
Class 2
Class 2
Class 1
Class 2
43