Siemens RUGGEDCOM RST2228 Installation Manual page 48

Table of Contents

Advertisement

Chapter 6
Certification
Test
a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
Dielectric Strength
Damped Oscillating Magnetic Field
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
42
Description
DC Power Ports
AC Power Ports
HV Impulse
DC Power Ports
AC Power Ports
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Ports
Description
Cold Temperature
Dry Heat
Test Levels
Signal Ports
5 kV (Fail-Safe
Relay Output)
35 V/m (80% modulation)
± 4 kV @ 2.5 kHz
2.5 kV common mode
2.5 kV common and 1.0
kV Differential Mode
2.5 kV common and 1.0
kV Differential Mode
5 kV (Failsafe Relay)
2 kV (Failsafe Relay Output)
100 A/m (peak) for 1 s
(100 kHz and 1 MHz)
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Installation Guide
Severity Levels
2.9 kVdc
2 kV
5 kV
5 kV
Test Levels
Severity Levels
± 8 kV
± 15 kV
± 4 kV
± 4 kV
± 4 kV
5 kV
5 kV
2.9 kVdc
2 kV
Severity Levels
EMC and Environmental Type Tests
RUGGEDCOM RST2228
5

Hide quick links:

Advertisement

Table of Contents
loading