F1: Whole Cleaner Unit; F2: Drum - Toshiba e-STUDIO 5540C Service Manual

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 5540C:
Table of Contents

Advertisement

Items to check
F14
VOC filter-1
F15
VOC filter-2

* F1: Whole cleaner unit

Remove any toner on the waste toner section of the drum cleaner unit and the upper section of
the EPU tray toner duct.

* F2: Drum

1. Handling precautions
If fingerprints or oil adhere to the surface of the drum, its properties may degrade, affecting
the quality of the copy image. So, wear gloves to avoid touching the drum surface with your
bare hands. Be sure to handle the drum carefully when installing and removing it so as not to
damage its surface.
After you installed the process unit to the equipment, there may be grease at the inner side of
the drum flange (shown as "B" in the figure below) that was transferred from the drum
coupling. So hold the levers (shown as "A" in the figure below) when you hold the drum or the
drum cleaner unit. Do not hook your finger on the flange hole on the rear side.
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
Lubrica
Cleaning
tion/
(x 1,000
Coating
sheets)
496/550/606
496/550/606
Fig. 7-20
Fig. 7-21
7 - 23
Replacement
Operation
(x 1,000 drive
check
counts)
532
532
A
B
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
PREVENTIVE MAINTENANCE (PM)
Parts
list