Section 2
2.

THE 1010BX INSTALLATION MENU

Programming System 1010BX requires no special experience or training. This field manual
contains all the necessary information. If you intend to connect this instrument to an external
device, then please have the instruction manual for the device available for reference.
The following paragraphs present a generic menu reference that applies to the Interface De-
tector and other configurations of System 1010 meters.
This section contains a general description of how to enter site setup data via the 1010BX
Installation Menu. It assumes that you have already selected a meter type as described in
the Section 1. For convenience, the manual presents the Installation Menu in the same se-
quence as it appears on the menu screen. Please note, however, that it is not necessary to
program the meter sequentially.

Review of Manual Conventions

When the text refers to a sensor or keyboard key, it will be enclosed in "less than" (<) and
"greater than" (>) symbols: e.g., <MENU>, <ENT>, <Up Arrow>, etc. Where a visual of the
key is shown; this means press this key.
When the text refers to a menu or menu cell name, it will be enclosed with square brackets:
e.g., [Pipe Data], [Channel Enable], etc.
Each menu includes an image of its main screen and a diagram of its structure. The rightmost
column of the structure diagram lists the option list choices of the menu cell, if applicable.

Review of Installation Menu Notes

If a power failure occurs while you are entering or editing data, the entered data may not be
retained in Active Memory.
Although you can operate the meter immediately after completion of a site setup, we rec-
ommend that you preserve your settings by saving them under a site name. Site data can be
saved at any time before invoking [Recall Site Setup] or [Create/Rename Site] commands.
These commands overwrite all data present in Active Memory.
We do not recommend that you attempt to operate the Interface Detector at a new site by
recalling and then editing an existing site setup. Each site must have its own set of trans-
ducer install parameters, even if the data from the recalled site setup is identical. Always
issue the [Create/Rename Site] to begin a new site setup. This will fill all the menu cells
with defaults to eliminate the possibility of retaining unwanted parameters.
The meter allows you to create your own personal site setup defaults. After creating a site
setup and editing default parameters as desired, save the site using the name [FASTSTRT].
The next time you issue the [Create/Name Site] command, your custom parameters will
become the systems defaults.
Siemens Hardware
2-1
1010BXFM-3