1.13

NAVIGATING THROUGH THE INSTALLATION MENU

After successfully accessing the Installation Menu, you can begin to set up the 1010BX. The
following table shows the PC keyboard Installation Menu navigation keys.
PC KEYBOARD
MENU
<UP Arrow>
<DOWN Arrow>
<RIGHT Arrow>
<RIGHT Arrow> (during Install) Allows manual frequency selection.
<LEFT Arrow>
^L (Ctrl L)
<ENT>
<Enter> (during Install)
<Backspace> or <DEL>
| (bar) Shift + \ (back slash)
Digits
@
1.14

USING THE 1010BX RESET SEQUENCE

Should you encounter an operating problem that blocks access to the System Menu, or the
meter operates erratically after exposure to a power transient or some other traumatic event,
this might require the use of the reset sequence in order to restore proper operation. System
1010BX provides two system resets. The first uses the magnetic wand and the second method
uses a PC command sent via the RS-232 interface (providing you have access to the flow com-
puter in this way). This section describes both system reset methods.
The reset sequence operates on two levels. The first level deletes all the data currently in
Active Memory, but leaves Datalogger data and all stored Site Setups intact. This is the most
desirable method since to restore operation all you have to do is reload a saved Site Setup. If
this fails then you have to use the second level, which clears ALL Dynamic Memory. Be aware
that this action erases all saved Site Setups (including flow calibrated sites), any logged
data and any user-defined pipe and transducer tables. This will require you to re-initialize the
Siemens Hardware
meter and transducers and repeat all desired site settings, custom pipe tables, etc.
DESCRIPTION
Enter Installation Menu.
Move up one menu cell (or change Flow Display screen).
Move up one menu cell (or change Flow Display screen).
Move right one menu cell.
Move left one menu cell. Repeated <LEFT Arrow> exits
Menu and Display screen.
Exits Menu.
Enter data and re-enter menu from Flow Display screen.
Forced Transmit test mode (Version 3 software)
Deselect list selection or zero numeric entry.
Change number sign or type (-) minus key.
Numerals zero through 9.
Decimal Point.
System Reset (refer to paragraph 1.14).
1-23
1010BXFM-3