The I/O Data Control Menu; The I/O Data Control Menu Structure - Siemens SITRANS F FUH1010 Series Operating Instructions Manual

Nema 7 compact interface detector
Table of Contents

Advertisement

Section 2
To deselect Datalogger Events:
Move the cursor to the item by pressing
Note that this removes the plus sign (+) from the item.
After selecting all desired items press
2.8

THE I/O DATA CONTROL MENU

This menu becomes available after picking a Meter Type and Channel/Path. Use it to assign
functions for the meter's analog outputs and optional inputs. The Analog Out Setup assigns
functions to the meter's current, voltage and pulse rate outputs. Each menu cell presents an
option list of the available data items. In addition, you can set up the alarm relays and enable
and span the analog input ports.
Use this menu to assign
data functions to Analog
Outputs.
Use this menu to assign
alarm functions to relay
outputs.
Use this menu to assign a
function to channel Relays.

THE I/O DATA CONTROL MENU STRUCTURE

I/O Data Control
Controlotron
Dual Path
Assign Data to Analog Outputs
Analog Output Setup
Relay Setup
Analog Inp Setup
I/O Data Control
Analog Output Setup
Relay Setup
2-46
and then press
CLR
to leave the [Datalogger Events] option list.
SITE 1
Io1
Io2
Relay 1
1010BXFM-3
Use this menu to
enable and span
optional Analog
Inputs.
LiquIdent m/s
API
Kg/m3
Base S.G.
Base API
Base Kg/m
3
Viscosity
T1
ROC
Iin1
Iin2
Vs
Valc
Vaer
Vsg
*See Io1 option list
Power On
High Liquident
Low Liquident
(continued)