Troubleshooting - BEA CONDOR User Manual

Motion and presence sensor for automatic industrial doors for normal to high mounting 3.5-6 m/for low mounting 2-3.5 m
Hide thumbs Also See for CONDOR:
Table of Contents

Advertisement

TROUBLESHOOTING

The door remains
closed and the LED
is OFF.
The infrared sensor
does not react.
The door opens for
no apparent reason.
The vehicle detection
filter is used, but
pedestrians are still
detected.
The door opens
and closes
constantly.
Sporadic presence
detections for no
reason.
The red LED is
permanently ON
after a setup.
The setup lasts more
than 30 seconds.
The sensor does not
unlock and the red
LED flashes quickly.
The sensor does
not respond to the
remote control.
The sensor power is off.
The infrared power emission
is too low according to the
mounting height.
The sensor detects raindrops
or vibrations.
The sensor is not installed
properly.
In highly reflective
environments, the sensor
detects objects outside of its
detection field.
The chosen value is not
optimal for the application.
The sensor is disturbed
by the door motion or
vibrations caused by the
door motion.
The presence detection is
disturbed by rain or lamps.
The sensor is not installed
properly.
The sensor has failed the
IR-setup.
The setup is disturbed.
Another sensor causes
interferences.
The sensor needs an access
code to unlock.
The remote control
batteries are weak or
improperly installed.
The remote control is badly
pointed.
The sensor is not powered.
1
Check the wiring and the power supply.
1
Launch a new setup.
Step out of the detection field!
1
Make sure the detection mode is unidirectional.
Increase the detection filter value.
2
1
Fasten the sensor firmly.
1
Change the antenna angle.
2
Decrease the field size.
3
Increase the detection filter value.
1
Increase the detection filter value.
2
Decrease the sensor angle.
3
Increase the mounting height.
1
Make sure the sensor is fixed properly.
2
Make sure the detection mode is unidirectional.
3
Increase the sensor angle and/or radar angle.
4
Increase the detection filter value.
5
Reduce the field size.
1
Set the IR-curtain immunity to value 3.
1
Fasten the sensor firmly.
Launch a new setup.
1
Step out of the detection field!
Make sure the detection field is clear and
1
launch a new setup.
1
Select a different frequency for each sensor.
Enter the right access code.
1
If you do not know the access code, cut the power
2
supply and restore it to access the sensor and
change the access code or delete it.
1
Check the batteries and change them
if necessary.
1
Point the remote control towards the sensor.
1
Check the power supply of the sensor.
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Condor xl

Table of Contents