Swing Motors - Daikin CTKM28PV2S Service Manual

Removal procedure
Table of Contents

Advertisement

Si041351ED

6. Swing Motors

Warning
Caution
Step
1. Remove the swing motors
for horizontal blades.
1
Release the interlock
rod.
2
Remove the screw at
the rear of the indoor
unit.
3
Remove the 2 screws
(front and rear).
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
When reassembling, do not confuse the installing order of the 2 motors for horizontal
blades and the colors of the connectors.
If you set the connectors or motors opposite, the horizontal blades do not move
smoothly or noise may be heard.
Procedure
Interlock rod
(R9546)
(R16296)
(R16297)
Swing Motors
Points
15