Example 4-17 Confirming the hardware connections
# lshwconn bpa -T lpar
40.6.0.2: 40.6.0.2: side=b,ipadd=40.6.0.2,alt_ipadd=unavailable,state=LINE UP
40.6.0.1: 40.6.0.1: side=a,ipadd=40.6.0.1,alt_ipadd=unavailable,state=LINE UP
# lshwconn bpa -T fnm
40.6.0.1: 40.6.0.1: side=a,ipadd=40.6.0.1,alt_ipadd=unavailable,state=LINE UP
40.6.0.2: 40.6.0.2: side=b,ipadd=40.6.0.2,alt_ipadd=unavailable,state=LINE UP
# grep 78AC /var/opt/isnm/hdwr_svr/data/HmcNetConfig
BPC 40.6.0.1 -tooltype=lpar -netc=y
-authtok=00F16D49F49205ED7B15322F8E88196C506235B4DA840D532A81CEDB7868B5E3B5CBF59B9
419613766C28BB0ED8F262F827E95CB3BAECDD8C5700F75EA058C5DF158AE26419C6E5255
-authtoklastupdtimestamp=2147483647 -mtms=78AC-100*992003H -slot=A -ignorepwdchg=n
BPC 40.6.0.1 -tooltype=fnm -netc=y
-authtok=00F16D49F49205ED7B15322F8E88196C506235B4DA840D532A81CEDB7868B5E3B5CBF59B9
419613766C28BB0ED8F262F827E95CB3BAECDD8C5700F75EA058C5DF158AE26419C6E5255
-authtoklastupdtimestamp=2147483647 -mtms=78AC-100*992003H -slot=A -ignorepwdchg=n
BPC 40.6.0.2 -tooltype=lpar -netc=y
-authtok=00F16D49F49205ED7B15322F8E88196C506235B4DA840D532A81CEDB7868B5E3B5CBF59B9
419613766C28BB0ED8F262F827E95CB3BAECDD8C5700F75EA058C5DF158AE26419C6E5255
-authtoklastupdtimestamp=1319637503483 -mtms=78AC-100*992003H -slot=B
-ignorepwdchg=n
BPC 40.6.0.2 -tooltype=fnm -netc=y
-authtok=00F16D49F49205ED7B15322F8E88196C506235B4DA840D532A81CEDB7868B5E3B5CBF59B9
419613766C28BB0ED8F262F827E95CB3BAECDD8C5700F75EA058C5DF158AE26419C6E5255
-authtoklastupdtimestamp=1319637533657 -mtms=78AC-100*992003H -slot=B
-ignorepwdchg=n

4.2.4 Checking FSP status, resolving configuration or communication issues

The lsnwloc command provides a list of the FSPs and their states as seen by CNM (see
Example 4-18).
Example 4-18 List of the FSPs and their states
# lsnwloc
FR006-CG04-SN051-DR1 RUNTIME
FR006-CG03-SN051-DR0 RUNTIME
FR006-CG13-SN005-DR2 RUNTIME
FR006-CG12-SN005-DR1 RUNTIME
FR006-CG10-SN004-DR3 RUNTIME
FR006-CG11-SN005-DR0 RUNTIME_CNM_EXCLUDED
FR006-CG05-SN051-DR2 RUNTIME
FR006-CG09-SN004-DR2 RUNTIME_CNM_UNREACHABLE
FR006-CG07-SN004-DR0 RUNTIME
FR006-CG08-SN004-DR1 RUNTIME
FR006-CG14-SN005-DR3 RUNTIME
FR006-CG06-SN051-DR3 RUNTIME
The following list of valid FSP states are returned from the lsnwloc command:
STANDBY: FSP is powered on, LNMC is running, and the Power 775 CEC is not powered
on.
FUNCTIONAL_TORRENT: The Power 775 in the process of powering on.