3.5.10 Diskless resources for NIM, iSCSI, NFS, and TFTP
Use Table 3-9 on page 232 for the configuration listing details for this section. For more
information, see Table 3-1 on page 158.
3.6 Component monitoring examples
This section describes monitoring examples.
3.6.1 xCAT for power management, hardware discovery, and connectivity
If the expected state for a specific group is all nodes online and in a running state,
Example 3-68 shows the following issues:
The hostname is missing in /etc/hosts.
Three LPARs are inactive (the operating system is not running).
One LPAR is running but is not pinged.
Example 3-68 Three nodestat output problems
# nodestat lpar -p
c250f10c12ap18-hf0: Please make sure c250f10c12ap18-hf0 exists in /etc/hosts
c250f10c12ap01: sshd
c250f10c12ap02-hf0: sshd
c250f10c12ap05-hf0: sshd
c250f10c12ap09-hf0: sshd
c250f10c12ap13-hf0: sshd
c250f10c12ap17: noping(Running)
c250f10c12ap21-hf0: noping(Not Activated)
c250f10c12ap25-hf0: noping(Not Activated)
c250f10c12ap29-hf0: noping(Not Activated)
3.6.2 Integrated Switch Network Manager
Example 3-69 shows the lsnwloc output.
Example 3-69 lsnwloc command output
# lsnwloc
FR010-CG14-SN008-DR3 RUNTIME_CNM_EXCLUDED
Chapter 3. Monitoring assets
241