RC7M Controller Specifications (2) (HS-G series)
Item
Environmental conditions
(in operation)
Power source
Degree of protection
Weight
Temperature: 0 to 40C
Humidity: 90% RH or less (no condensation allowed)
Three-phase, 200 VAC-15% to 230 VAC+10%, 50/60 Hz, 1.8 kVA
Single-phase, 230 VAC-10 to 230 VAC+10%, 50/60 Hz, 1.8 kVA
IP20
Standard type:
Global type with safety board: Approx. 18 kg (40 lbs)
Global type with safety box:
WARNING
DO NOT touch fins. Their hot surfaces may cause severe
burns.
DO NOT insert fingers or foreign objects into openings.
Doing so may cause bodily injury.
Before opening the controller cover and accessing the inside
of the controller for maintenance, be sure to turn off the
power switch, disconnect the power cable, and wait 3
minutes or more. This is for protecting you from electric
shock.
DO NOT connect or disconnect connector to/from the
controller while the power switch is on. Doing so may cause
electric shock or controller failure.
CAUTION IN INSTALLATION
This controller is not designed to be dust-proof,
splash-proof, or explosion-proof.
Read operation-manuals before installation.
Do not place anything on the controller.