Transponder
7.19 MDS D425
7.19.4
Technical specifications
Table 7- 48
Product type designation
Memory
Memory configuration
•
•
•
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
•
•
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
•
•
Degree of protection to EN 60529
Shock-resistant to IEC 68-2-27
Vibration-resistant to IEC 68-2-6
Torsion and bending load
264
Technical specifications for the MDS D425
UID
User memory
OPT memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D425
8 bytes
•
2000 bytes FRAM
•
16 bytes FRAM
•
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
6
Plastic PA 6.6 GF
•
Black
•
> 0 mm
Inductive, without battery
-25 to +85 ℃
•
-40 to +125 ℃
•
IP68
•
2 hours, 2 bar, +20 °C
IPx9K
•
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
50 g
1)
20 g
1)
Not permitted
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-4AG00
SIMATIC RF200