Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Pressure resistance
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
The values for shock and vibration are maximum values and must not be applied continuously.
1)
) To prevent it loosening during operation, secure the screw with screw locking varnish.
2
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Material
Color
During operation
During transportation and storage
Plastic PPS
Black
> 0 mm
Inductive, without battery
-25 to +85 ℃
-40 to +100 ℃
IP68
2 hours, 2 bar, +20 °C
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
50 g
1)
20 g
1)
Low pressure resistant
vacuum dryer: up to 20 mbar
High pressure resistant
(see degree of protection IPx9K)
Not permitted
30 x 8 mm
15 g
1 x M4 screw
2)
≤ 1 Nm
Transponder
7.17 MDS D423
6GT2600-4AA00
257