5.5.5

Technical specifications of the RF250R reader

Table 5- 5
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Maximum range
Maximum data transmission rate reader ↔ tran-
sponder (tag)
Typical transmission time for user data per byte
Baud rate
Read/write distances of the reader
Interfaces
Electrical connector design
Standard for interfaces for communication
Antenna
Mechanical specifications
Housing
Recommended distance to metal
Supply voltage, current consumption, power loss
Supply voltage
Typical current consumption
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Technical specifications of the RF250R reader
Read
Write
for write access
for read access
6GT2821-5AC10
6GT2821-5AC11
Material
Color
SIMATIC RF250R
13.56 MHz
35 mm
ISO tags
approx. 1500 bytes/s
approx. 1500 bytes/s
0.6 or 1.2 ms
0.6 or 1.2 ms
19200, 57600, 115200 Bd
see section "Field data (Page 37)"
M8, 4-pin
RS-422 (3964R protocol)
RS-232 (ASCII protocol)
external, ANT 8, ANT 12, ANT 18, ANT 30 can
be connected
Plastic PA 6.6
Anthracite
0 mm
24 VDC
50 mA
Readers
5.5 SIMATIC RF250R
6GT2821-5AC10
6GT2821-5AC40