5.5.5
Technical specifications of the RF250R reader
Table 5- 5
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Maximum range
Maximum data transmission rate reader ↔ tran-
sponder (tag)
•
•
Typical transmission time for user data per byte
•
•
Baud rate
Read/write distances of the reader
Interfaces
Electrical connector design
Standard for interfaces for communication
•
•
Antenna
Mechanical specifications
Housing
•
•
Recommended distance to metal
Supply voltage, current consumption, power loss
Supply voltage
Typical current consumption
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Technical specifications of the RF250R reader
Read
Write
for write access
for read access
6GT2821-5AC10
6GT2821-5AC11
Material
Color
SIMATIC RF250R
13.56 MHz
35 mm
ISO tags
approx. 1500 bytes/s
•
approx. 1500 bytes/s
•
0.6 or 1.2 ms
•
0.6 or 1.2 ms
•
19200, 57600, 115200 Bd
see section "Field data (Page 37)"
M8, 4-pin
RS-422 (3964R protocol)
•
RS-232 (ASCII protocol)
•
external, ANT 8, ANT 12, ANT 18, ANT 30 can
be connected
Plastic PA 6.6
•
Anthracite
•
0 mm
24 VDC
50 mA
Readers
5.5 SIMATIC RF250R
6GT2821-5AC10
6GT2821-5AC40