Technical specifications - output
Regulation
Short-circuit current I
Settling time t
Temperature coefficient ε
Overload behavior P
Short-circuit protection/
No-load response
Derating
Connector type
Technical specifications - initial configurations
Input
110 VAC
110 VAC
220 VAC
220 VAC
Technical specifications - standards complied with
Designation
Electrical safety
Conducted interference
Emission
All values are measured at full-load and at an ambient temperature of +25 ℃ (unless
specified otherwise).
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Line regulation
Load regulation
max
load variations
R
over
Outputs U1 = U2
24 VDC
24 VDC
24 VDC
24 VDC
U
= min./max.
in
I
= 10...90...10 %
out
I
= 4 A (+50 °C)
nom
I
= 10 ... 90 ... 10 %
out
T
= -25 °C to +70 °C
A
T
> +50 °C to +70 °C
A
ILoad = I1 + I2
0 A
3 A
0 A
3 A
Standard
EN 60950 / UL 60950 / CAN/CSA 22.2 950, 3 Edition
EN 61000-6-3
EN 55011
EN 61000-6-3
EN 55011
A.2 Accessories
≤ 1,0 %
≤ 1,0 %
105 ... 130 % I
nom
< 5 ms
0.01 %/K
Constant current
Continuous/no-load stability
max. 2 %/K
M12, 4-pin;
two sockets
Efficiency (%)
Remarks
No-load stability
≥ 88
No-load stability
≥ 90
Values
Class B
Class B
Appendix
325