10 PARAMETERS

10.1 DISPLAY PARAMETERS

To perform a configuration / modification of parameters that control the elevator, follow these steps:
Once you open STARTER, click in the menu on the "+" sign to the left side of the S120 device (pos. 1),
1.
and then the "+" sign on the side of Drive_1 (pos. 2) to expand the tree. Then select the expert list (pos.
3).
2.
If the top center of the screen displays only a single sheet with written expert list (pos. 4), then click on
the button
(pos.5) and open the list "User S120 Low" which will allow you to view a list of simple
parameters (recommended), useful for setup and quick commissioning of the inverter.
If S120 User files are not present, you can copy them from another project (typically saved to the
path: S7Proj\projectname\u7\cdldata, where projectname is the name of a previously saved project), or
pick them up from the initial configuration that was provided by Omarlift with the drive, or even request
them to Omarlift.
1
2
3
Figure 55- STARTER screen parameter list
Otherwise, if the list "User S120 Low" is available now from those at the top center of the screen (pos. 4),
select it.
The list of "User S120 HIGH", instead, provides tools for advanced configuring and commissioning the
inverter, and is recommended only for experienced users with an indication of Omarlift.
In the list, the parameters are grouped into families based on the range of intervention and for each
parameter, as well as a numeric identifier, there is a description of the function performed.
The parameters highlighted in green are the only user-modifiable.