Technical Data - Siemens S120 Instructions Manual

For hi power units
Hide thumbs Also See for S120:
Table of Contents

Advertisement

3.2.4

Technical data

Table 7 Technical data, Power Modules Chassis
Line voltage 3-ph. 380 V to 480 V AC ±10% (-15% < 1 min)
Order number
Frame size
Output current
rated current In
base load current IL
base load current IH
for S6 duty (40 %) IS6
peak current Imax
Supply voltages
Electronics power supply
Overvoltage trip
Undervoltage trip
Type rating¹)
on basis of In
on basis of IH
Rated pulse frequency
without derating
with derating
Power loss
Cooling air requirement
Sound pressure level at 50/60 Hz
Rated input current
Current requirement ²) at 24 V DC, max.
NH fuses
Rated current
Fuses UL Class J
Rated current
Short-circuit current rating SCCR
Circuit-breaker type designation IEC 60947
rated current
Circuit breaker type designation
UL489 / CSA C22.2 No. 5-02
Rated current
Short-circuit current rating SCCR
Line supply connection
U1, V1, W1
Motor connection
U2, V2, W2
DC link connections DCPA, DCNA, (option,
Braking Module)
DC link connections DCPS, DCNS (option, dV/dt
filter)
PE connection
Max. motor cable length³)
Max. ambient temperature
without derating
with derating
Degree of protection
Width
Height
Depth
Weight
¹) Rated power of a typical standard induction motor at 400 V 3 AC
²) Current consumption of Power Module only. If a Control Unit is supplied with 24 V DC from the Power
Module, its current consumption must be added.
³) Max. motor cable length 100 m (shielded) in conjunction with a line filter to comply with the EMC limit
values of EN 61800-3 Category C2.
⁴) Depth = 421 mm including front cover when a Control Unit is installed
Siemens S120_EN_rev06-08062017.docx
6SL3310-
1TE32-1AA3
FX
A
210
A
205
A
178
A
230
A
307
24 (20.4 ... 28.8)
VDC
VDC
820 ± 2 %
VDC
424
kW
110
kW
90
kHz
2
kHz
8
kW
2.46
m³/s
0.17
dB(A)
66/67
A
229
A
0.8
3NA3144
A
250
3NE1227
A
250
kA
65
3VL4725-1DC36-0AA0
200...250
A
3VL3125-3KN30-0AA0
A
250
kA
65
Flat connector for M10 cable lug,
max. connection crosssection 2x185mm²
Flat connector for M10 cable lug,
max. connection cross-section x185mm²
Flat connector for M6 cable lug, connection
cross-section 1x35 mm²
Flat connector for M8 cable lug, connection
cross-section 1 x 35 mm²
Flat
connector
connection cross-section 2 x 185 mm2
m
300 (shielded) / 450 (unshielded)
°C
40
°C
55
IP20 or IPXXB
mm
326
mm
1400
356 ⁴)
mm
kg
104
for
M10
cable
lug,
max.
3-19

Hide quick links:

Advertisement

Table of Contents
loading