Basic Settings - Siemens Sinumerik 840D sl Function Manual

Motion control information system
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

DNC IFC SINUMERIK - Downloading NC Data via a Network (FBDN2)
5 Configuration file

5.2.1 Basic settings

Fig. 5-2: Configuration user interface / Basic settings
The basic settings for the download or upload and operation on the PCU are
defined in the Basic settings tab.
Transfer target switchable via softkey
This parameter specifies whether the default transfer target for the download from
DNC can be switched via a Select softkey:
Checkbox activated = Select softkey available 
Checkbox deactivated = Select softkey not available 
Extract from the configuration file:
Section [GLOBAL]
ToggleSK = Y
Target
This parameter specifies the default transfer target for the download from DNC:
PCU = The NC data is transferred to the file system
NCK = The NC data is transferred to the NC and loaded
Extract from the configuration file:
Section [GLOBAL]
DefaultTransfer = PCU