Connect The Gas Line - Superior Fireplaces DRT3035DEN-C Installation And Operation Instructions Manual

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT3000-C Series Direct-Vent Gas Fireplaces
See the Operation section on Page 51 for more details.
NOTE: Electronic models must be connected to the main power supply.
1. Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.
2. Remove the electrical inlet cover plate from the side of the unit by removing the plate's securing screws (Table 12).
3. If unit is not supplied with a strain relief, remove the cover plate knockout. Then, feed the power supply wire
through the knockout opening and into the unit junction box.
4. Connect the black power supply wire to the lower outlet's red pigtail lead (Figures 29-30). Connect the white
power supply wire to the outlet's common terminal.
5. Connect the ground supply wire to the pigtail lead attached to the outlet's green ground screw. Restrain the inlet
power lead per NEC or local codes.
6. If a wall-mounted ON/OFF control, High/Low switch, or thermostat is to be used, mount it in a convenient location on a wall
near the fireplace.
7. If an optional control is to be used, wire it in the low voltage circuit (Figure 30).
NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit
and the other end of each conductor placed loose inside the bottom compartment.
8. After the wiring is complete, replace the cover plate.
Figure 30 - Wiring Diagram—Electronic Gas Valve
B
HI/LOW
SWITCH
R
B
2B 1B
BL
O
2
1
B
2A
1A
G
1
2
W
ON/OFF WALL
SWITCH
WIRING COLOR CODE
B = BLACK
BR = BROWN
GY = GRAY
PU = PURPLE
R = RED
Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in
connecting the electronic components to the junction box in the lower compartment. This grounding plug
provides protection against shock hazard and should be plugged directly into a properly grounded three-
prong receptacle. DO NOT cut or remove the grounding prong from the plug.
JUNCTION BOX
120V AC
B
HOT
W
NEUTRAL
G
GROUND
BATTERY
B
HOLDER
R
O
O
SPLIT
FLOW
BL
BL
G
W
BL = BLUE
G = GREEN
O = ORANGE
W = WHITE
Y = YELLOW
AC/DC
POWER
ADAPTOR
PROFLAME VALVE
B
R
Y
G
O
B
R
BATTERY
HOLDER
B
R
WARNING
SIT Electronic
Gas Valve
ELECTRONIC PILOT ASSEMBLY
HOOD
B
PILOT TUBE
Y
SPARK WIRE CABLE
PILOT GROUND WIRE
Y
G
O
W
W
BL
R
B
G
CPI SWITCH
OFF (O) = INTERMITTANT PILOT MODE
W
ON (–) = STANDING PILOT MODE
BL
Installation
900966-00B, 04/2019
IGNITER ROD
FLAME SENSOR
B
PILOT
SENSOR
CABLE
PROFLAME
DFC BOARD
DFC WIRE HARNESS
39