Superior Fireplaces DRT3035DEN-C Installation And Operation Instructions Manual page 57

Direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
DRT3000-C Series Direct-Vent Gas Fireplaces
Installing the DRT3000-C 35 Series Log Set
The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is
critical to prevent sooting. Place the logs in the gaps between flame peaks, so they do not impinge the flames. Follow the log placement
instructions precisely.
NOTE: Do not cover the burner ports.
Table 30 - Log Set
I.D.
Description
No.
1
Rear Log
2
Left Twig Log
3
Right Twig Log
4
Middle Twig Log
1. If necessary, remove the glass door (Pages 63-64). Locate the placement tabs (Figure 40).
2. Bend up the two log tabs (Figure 40) and place embers as shown (Figures 40 and 41). Do not cover large ports with ember material.
Figure 40 - Locate and bend up the log placement tabs
a
Figure 41 - Place glowing embers (rockwool)
Do NOT place embers on or close
to large ports or the pilot area.
4
3
2
Tabs for
Log #1
Catalog number for the entire set: See Page 77.
1
4
2
b
NOTE: Enough glowing ember
material is provided for several
applications. For best glowing
effect, replace the ember material
annually.
Operation
900966-00B, 04/2019
1
3
Do not place ember
material in this area
57