MINIMUM CLEARANCES TO COMBUSTIBLES

Fireplace And Vent Clearances
The fireplace is approved with zero clearance to combustible materials
on all sides (Table 8), with the following exception: The unit may not
be recessed (allowance made for mantel legs / side trim in Figure 5).
When the unit is installed with one side flush with a wall, the wall on the
other side of the unit must not extend beyond the front edge of the unit
(Figure 5).
The fireplace must be mounted on a fully supported base extending
the full width and depth of the unit. The fireplace may be located on
or near conventional construction materials. However, if installed on
combustible materials, such as carpeting, vinyl tile or other combustible
material other than wood flooring, the appliance shall be installed on a
metal or wood panel extending the full width and depth of the appliance.
Hearth Extension
A hearth extension is not required with this fireplace. Any hearth extension used is for appearance only and does not have to conform to
standard hearth extension installation requirements.
Shelf Height
t
To provide for the lowest possible shelf surface, use the rear vent model. For top vent models, the venting attached to the top vent should
be routed in a way to minimize obstructions to the space above the fireplace. Do not insulate the space between the fireplace and the
area above it (Table 9). The minimum height from the base of the fireplace to the underside of combustible materials used to construct a
utility shelf in this fashion is shown in Table 9.
Table 9 - Combustible Shelf Height—Top Vent
Model
35" Models
40" Models
45" Models
CLEARANCES TO COMBUSTIBLES MUST BE MAINTAINED
No combustible materials or insulation is permitted in the shaded area
between the appliance and the shelf above it.
WARNING
LOWED CAN RESULT IN A SAFETY HAZARD!
* Includes 3" clearance to combustibles (required above vent components)
** In alternative, Rear Vent applications, Top Vent will be sealed as detailed in Installation Sequence Step 4 (Page 20).
Top Vent with one 90° Elbow *
Secure Vent
Secure Flex
®
(using rigid elbow)
(using flex elbow)
47" (1194 mm)
49" (1245 mm)
52" (1321 mm)
54" (1372 mm)
52" (1321 mm)
54" (1372 mm)
: CRITICAL INSTALLATION INFORMATION THAT IF NOT FOL-
Table 8 - Minimum Clearances *
Back ***
Top Standoffs
From Bottom of Unit to Ceiling
Front Service Clearance—
clearance immediately in front of
viewing area(s)
*
3" (77 mm) above any horizontal/inclined vent component.
** See Page 21 for clearance requirements to the nailing flange
located at each side of the unit and any screw heads adjacent to it.
*** When in top vent mode; no combustible material shall be allowed to
contact the rear flue cap/cover.
Alternative Rear Vent
applications **
®
Secure Vent
®
41" (1042 mm)
46" (1169 mm)
46" (1169 mm)
:
Installation
900966-00B, 04/2019
1-1/2" (38mm) to wrapper
0" (0 mm) to Spacers
1/2" (13 mm) to wrapper
Sides
0" (0 mm) to Spacers **
0" (0 mm) to top standoffs
Floor
0" (0 mm)
64" (1626 mm)
3" (77 mm)—Top *
Vent
1" (26 mm)—Sides and Bottom
36" (914 mm)
Shelf Height
(see table)
15