SECTION 3
Connecting External Devices

3-3 Linear Sensor Controller Connections

3-3-1 Crimp Terminals and Cables
3-3-2 Terminal Names
NOTICE
Z500
46
Setup Manual
The terminal block uses M3 terminal screws.
Use appropriate crimp terminals for M3 screws as shown below.
Tighten the screws to a torque of between 0.5 and 0.6 N·m.
Recommended Crimp Terminals
Type
Forked
6.0 mm max.
Round
6.0 mm max.
Re-cover the terminal blocks with the Terminal Block Protection Covers. Uncovered
terminal blocks can result in electric shock.
4to20mA -5to5V
0
Manufacturer
J.S.T. Mfg Co., Ltd.
J.S.T. Mfg Co., Ltd.
Analog output ground connected to input devices.
Analog output terminal for voltage output in the range -5 to 5 V.
Analog output terminal for current output in the range 4 to 20 mA.
Recommended
Model
wire size
V1.25-B3A
1.31 to 1.65 mm
V1.25-MS3
2