Mira Virtue Installation & User Manual page 24

Thermostatic mixer
Table of Contents

Advertisement

3.
Unscrew the inlet and outlet connectors.
4.
Remove the shower control.
5. Remove the filters.
6. Clean the filters under a jet of water to remove any lodged particles or replace
them.
7.
Reassembly is the reversal of the above procedure.
8.
Turn on the hot and cold water supplies and check for leaks.
Mira Virtue with Diverter
After a period of use the friction device on the parking socket may become loose,
this can be tightened as follows:
1.
Unscrew the ball.
2. Squeeze the parking socket sleeve together and pull out vertically.
3. Remove the parking socket sleeve from the hose.
4. Remove the hose, back through the parking socket.
5.
Tighten the screw.
6. Refit all the components in reverse order.
1353004-W2-A
Parking
Socket
Sleeve
Make sure the
split in the sleeve
is at the back
Tighten Screw
Through Here
Ball
Parking
Socket
24