Mira Virtue Installation & User Manual page 11

Thermostatic mixer
Table of Contents

Advertisement

Installation of Mira Virtue Mixer
Warning! Isolate the water supplies before installing the shower  .
1
The thermostatic mixer can be installed
with rear or falling supply inlets. Decide
on the most appropriate method for
your installation, and if necessary, the
inlet elbows can be swivelled to suit.
Note! The Mira Virtue with Diverter
cannot be installed with a falling
supply.
3
HOT
Fit the supply pipework: Hot - Left, Cold - Right. For rear entry supplies the inlet
pipework should extend 28 mm from the finished wall surface, for rising or falling
supplies the centre of the pipe should be set 35 mm from the finished wall surface.
Note! If it is not possible to install the mixer with this pipework configuration
complete the installation then refer to section: 'Reversed Inlet Supplies'.
2
Use the installation template to mark the
positions of the holes for the backplate
and the pipe centres.
For rising or falling supplies the pipe
positions should be set 35 mm from
the centre of pipe to the finished wall at
153 mm centres.
COLD
Elbow
Diameter 19 mm
x 2 mm deep
11
35 mm
28 mm from finished
wall surface
Ø19 mm
COLD
28 mm
HOT
1350004-W2-A
153 mm