11. Refit the hub and bearing. Make sure that the hub is positioned fully clockwise.
12. Refit indicator trim in the same orientation that you removed it. Note! Ensure
the lugs on the inside of the indicator trim matches up with the cut outs on the
valve body.
13. Refit the handle trim.
14. Fit the handle using washer and screw. Careful! Ensure that washer is
assembled when refitting the handle as this could lead to corrosion.
15. Tighten the screw to secure the handle.
Handle
16. Press and rotate the ceramic bezel clockwise by 90° to refit. Careful! There is
a spring behind the ceramic bezel.
17. Check that the showering temperature is correct.
Bezel Lugs Alignment
with Handle
Installed Ceramic Bezel
21