Table A- 1
Technical specifications
Dimensions W x H x D
Weight
Current consumption from 24 V
(24 V DC infeed via front panel connector)
Area, static
Area, dynamic
Polarity reversal protection
Electrical isolation
Current consumption from backplane bus
Power loss
Indicators
Interrupts
Diagnostic interrupt
Diagnostic functions
Diagnostic information can be read out
Supplied protocol drivers
Transmission rate with 3964(R) protocol
Transmission rate with RK 512 computer link
CP 341 Point-to-Point Communication, Installation and Parameter Assignment
Manual, 09/2008, A5E02191071-01
www.gkbpx.com
S7-300 Programmable Controllers, Module Specifications
General technical specifications
40 x 125 x 120 mm
0.3 kg
CP 341-RS 232C: Typ. 100 mA
CP 341-20mA-TTY typ. 100 mA
CP 341-RS 422/485: Typ. 100 mA
20.4 to 28.8 V
18.5 to 30.2 V
Yes
Yes, relative to all other voltages
Approx. 70 mA
CP 341-RS 232C: Typ. 2,4 W
CP 341-20mA-TTY: Typ. 2,4 W
CP 341-RS 422/485: Typ. 2,4 W
LEDs for transmitting (TXD), receiving (RXD) and
group faults (SF)
Programmable
Yes
ASCII driver
3964(R) procedure
RK 512 computer link
Printer driver
300, 600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, 76800, 115200 bps
(half-duplex)
300, 600, 1200, 2400, 4800, 9600, 19200, 38400,
57600, 76800, 115200 bps
(half-duplex)