YORK SETPOINT CHANGE LOG
CHILLER ID 0
(c) 1997 – 2001 YORK INTERNATIONAL CORPORATION
Fri 05 Oct 2001 4:48:04 PM
Log Entry 1 Evaporator - Leaving Chilled Local
Setpoint
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
Log Entry 2 Condenser - High Pressure Warning
Threshold
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
Log Entry 3 Condenser - Drop Leg
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
Log Entry 4 Evaporator - Refrigerant
---------------------------------------------------------------------------------
Date
Time
Access Level
User Id
Old Value
New Value
FIGURE 62 - SAMPLE PRINTOUT (SECURITY LOG
REPORT)
JOHNSON CONTROLS
YORK TREND
CHILLER ID 163
© 1997 – 2000 YORK INTERNATIONAL CORPORATION
MON 09 OCT 2000 3:33:47 PM
DATA 1: LEAVING CHILLED LIQUID TEMPERATURE
DATA 2: RETURN CHILLED LIQUID TEMPERATURE
= 05 Oct 2001
DATA 3: EVAPORATOR PRESSURE
= 4:23:49 PM
DATA 4: LEAVING CONDENSER LIQUID TEMPERATURE
= Service
DATA 5: RETURN CONDENSER LIQUID TEMPERATURE
= 4268
= 46.5 ~F
DATA 6: CONDENSER PRESSURE
= 48.0 ~F
TIME
3:33:47 PM
3:33:48 PM
= 05 Oct 2001
3:33:49 PM
= 1:36:12 PM
3:33:50 PM
= Service
3:33:51 PM
= 4268
= 162.5 Psig
= 225.0 Psig
FIGURE 63 - SAMPLE PRINTOUT (TREND DATA
= 05 Oct 2001
NEW OR EXISTING POINTS)
= 1:36:02 PM
= Service
= 4268
= Disabled
= Enabled
= 05 Oct 2001
= 1:35:48 PM
= Service
= 4268
= Disabled
= Enabled
YORK CUSTOM VIEW
CHILLER ID 0
(c) 1997 – 2001 YORK INTERNATIONAL CORPORATION
Mon 21 Jun 1999 1:28:25 PM
Leaving Chilled Liquid Temperature
Return Chilled Liquid Temperature = 55.0 ~F
Leaving Condenser Liquid Temperature
Return Condenser Liquid Temperature
Evaporator Saturation Temperature = 41.0 ~F
Condenser Saturation Temperature
Evaporator Pressure
Condenser Pressure
Psig
Oil Pressure
% Full Load Amps
FIGURE 64 - SAMPLE PRINTOUT (CUSTOM
SCREEN REPORT)
SECTION 4 - PRINTERS
DATA 1 DATA 2
DATA 3
DATA 4 DATA 5
45.5 °F
55.0 °F
39.0 PSIG
95.0 °F
45.5 °F
55.0 °F
39.0 PSIG
95.0 °F
45.5 °F
55.0 °F
39.0 PSIG
95.0 °F
45.5 °F
55.0 °F
39.0 PSIG
95.0 °F
45.5 °F
55.2 °F
39.1 PSIG
95.1 °F
DATA 6
85.0 °F
120.0 PSIG
85.0 °F
120.0 PSIG
85.0 °F
120.0 PSIG
85.3 °F
120.1 PSIG
85.4 °F
120.2 PSIG
4
= 45.0 ~F
= 95.0 ~F
= 85.0 ~F
= 78.5 ~F
= 70.0 Psig
= 140.0
= 45.0 Psid
= 50 %
157