SECTION 4 - PRINTERS
YORK SETPOINTS
SAMPLE CHILLER
YMC2-S-0703AA
SGWM-100000
YMC2 Chiller ID
1
(c) 2010 Johnson Controls
Tue 28 Jun 2011
7:59:24 AM
Software Versions
------------------------------------------------------
Controls
C.OPT.16.01.307
CC
BIOS
Kernel
GP
GUI
SIO
GPIC
Ext I/O
VSD Inverter
VSD Rectifier
VSD Modbus
System Information
------------------------------------------------------
Data Display Mode
System Language
Date Format
Control Source
Remote Analog Input Range
Line Voltage
Line Frequency
Chilled Liquid Pump Operation
Head Pressure Control
Hot Gas Bypass
Flow Switch Input
Power Failure Restart
Clock
Jumper Settings
-----------------------------------------------------
Liquid Type
Refrigerant Selection
Printer Setup
-----------------------------------------------------
Automatic Printer Logging
Log Start Time
Output Interval
Printer Type
Baud
Data Bits
Parity
Stop Bits
COM 2 Setup
------------------------------------------------------
Baud
Data Bits
Parity
Stop Bits

FIGURE 58 - SAMPLE PRINTOUT (SETPOINTS)

152
Evaporator
-----------------------------------------------------
Leaving Chilled Local Setpoint
Leaving Chilled ISN Setpoint
Leaving Chilled Modem Setpoint
Leaving Chilled Analog Setpoint
Leaving Chilled Digital Setpoint
Remote Range
Restart Offset
Restart Temperature
Shutdown Offset
=
Shutdown Temperature
Brine Low Evaporator Cutout
= 3.05
Smart Freeze
= C.OPT.00.02
Refrigerant
= 1.21
= 1.09
Condenser
= 0.44
-----------------------------------------------------
= 1.25
High Pressure Warning Threshold
= 0.13.e.8
Head Pressure Setpoint
= C.EXP.01.00
=
Type
C.HYP.04.01.02
=
PID Output
C.HYP.03.01.02
= 04.01
Surge
-----------------------------------------------------
Surge Sensitivity
Shutdown
= English
Count Limit
= English
Count Window
= DD MMM YYYY
Refrigerant Level Control
= ISN
-----------------------------------------------------
= 0-10 Volts
Refrigerant Level Setpoint
= 460V
Startup Position
= 60Hz
Startup Delay
= Standard
Ramp Time
= Disabled
Zone Transition Delta
= Enabled
Zone Transition Time
= J14
Level Control Zone 1 Proportional
= Auto
Level Control Zone 1 Integral
= Enabled
Level Control Zone 1 Derivative
Level Control Zone 2 Proportional
Level Control Zone 2 Integral
Level Control Zone 2 Derivative
= Water
= R134a
Variable Geometry Diffuser
-----------------------------------------------------
PRV VGD Inhibit
PRV Offset
= Disabled
Surge React Time
= 12:00 AM
Surge Wait Time
= 60 Min
Probe Wait Time
= Okidata
Open Pulse
= 9600 Baud
High Limit
= 8 Bits
Low Limit
= None
Broadband Threshold
= 1 Bit
100% VGD Voltage
0% VGD Voltage
VGD Calibrated
= 38400 Baud
= 8 Bits
= None
= 2 Bits
FIGURE 58 - SAMPLE PRINTOUT (SETPOINTS)
(CONT'D)
FORM 160.78-O2
ISSUE DATE: 5/22/2017
= 42.0 ~F
= 42.0 ~F
= 45.0 ~F
= 42.0 ~F
= 42.0 ~F
= 10.0 ~F
= 2.0 ~F
= 44.0 ~F
= 4.0 ~F
= 38.0 ~F
= 25.0 PSIG
= Off
= Enabled
= 162.5 PSIG
= 23.0 PSIG
(when HPC is Enable)
= 0-10V
(when HPC is Enable)
= Direct
(when HPC is Enable)
= 0.3
= Enabled
= 15
= 3 Min
= 50.0 %
= 45.0 %
= 0 Min
= 1 Min
= 5.0 %
= 10 Sec
= 0.50
= 1.00
= 0.00
= 0.70
= 2.50
= 0.00
= 100 %
= 3 %
= 5 Sec
= 0.5 Min
= 0.5 Min
= 5 Sec
= 0.50 V
= 0.45 V
= 0.18 V
= 3.21 V
= 2.03 V
= True