Clearance And Ventilation; Electrical Grounding Requirements; Australian Requirements - Frymaster FQE60U FilterQuick easyTouch Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

This appliance must be connected to a power supply having the same voltage and phase as
specified on the rating plate located on the inside of the appliance door.
All wiring connections for this appliance must be made in accordance with the wiring diagram(s)
furnished with the appliance.
appliance door when installing or servicing this equipment.
Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over,
and cause injury. The appliance area must be kept free and clear of combustible material at all
times.
Building codes prohibit a fryer with its open tank of hot oil being installed beside an open flame
of any type, including those of broilers and ranges.
In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power
switch OFF. Do not attempt to start the fryer(s) until power is restored.

2.1.1 Clearance and Ventilation

This appliance must be kept free and clear of combustible material, except that it may be installed on
combustible floors.
A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible
construction.
A minimum of 24 inches (61cm) should be provided at the front of the equipment for
servicing and proper operation.
Do not block the area around the base or under the fryers.
2.1.2

Electrical Grounding Requirements

All electrically operated appliances must be grounded in accordance with all applicable national and
local codes, and, where applicable, CE codes. All units (cord connected or permanently connected)
should be connected to a grounded power supply system. A wiring diagram is located on the inside of
the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.
The equipotential grounding lug allows all the equipment in the same location to be
electrically connected to ensure there is no electrical potential difference between the
units, which could be hazardous.
2.1.3

Australian Requirements

To be installed in accordance with AS 5601 and AS/NZS 3000:2007 local authorities, gas, electricity, and
any other relevant statutory regulations.
If casters are fitted, the installation must comply with AS5601 and AS1869 requirements.
DANGER
DANGER
Refer to the wiring diagram(s) affixed to the inside of the
DANGER
DANGER
WARNING
2-2