Ventilation Requirements; Extraction Of The Products Of Combustion; Connection To Gas - Smeg CE6GPXU Instructions For Installation And Use Manual

Smeg oven instructions for installation and use
Hide thumbs Also See for CE6GPXU:
Table of Contents

Advertisement

15.2 Ventilation requirements

The room containing the appliance should have an air supply in accordance with the standards in force.
The room where the appliance is installed must have enough air flow as required for the regular
combustion of gas and by the necessary air exchange of the same room. The air vent, protected by
grills, must be suitably dimensioned in compliance with the current regulations and positioned so that no
part of it is obstructed.

15.3 Extraction of the products of combustion

Extraction of the products of combustion must be ensured by means of hoods connected to a natural
draught chimney whose efficiency is assured or via forced extraction. An efficient extraction system
requires precision planning by a specialist qualified in this area and must comply with the positions and
distances indicated by the regulations. When the job is complete, the installer must issue a certificate of
conformity.

15.4 Connection to gas

Installation of the UNI-CIG 7140 compliant rubber hose must be carried out so that the hose length is no
greater than 1.5 metres. Make sure that the hose does not come into contact with moving parts or is
squashed. The inside diameter of the hose must be 8 mm for LPG. LIQUID and 13 mm for METHANE
GAS
Verify that all the follow conditions are met:
• the hose is fixed to the hose connection with safety clamps;
• no part of the hose is in contact with the hot walls (max. 50 °C);
• the hose is not under traction or tension and has no tight curves or twists;
• the hose is not in contact with sharp objects or sharp corners;
• if the hose is not perfectly airtight and leaks gas, do not try and repair it: replace it with a new hose;
• verify that the hose is not beyond its life cycle (serigraphed on the hose itself).
CONNECTION USING RUBBER HOSES COMPLYING WITH THE CURRENT REGULATIONS IS
ONLY PERMITTED IF THE HOSE CAN BE INSPECTED ALONG ITS ENTIRE LENGTH.
15.4.1 Connection of natural
Make the connection to the gas mains using a rubber hose whose
specifications comply with the current regulations (verify that the reference
standard is stamped on the hose).
Screw the hose connector A to the gas connector B of the appliance, placing
with the seal Cbetween them. Push the rubber hose D onto the hose
connector A and secure it with the clamp E that is compliant with the current
standard.
58
Instructions for the installer

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ce6gpx

Table of Contents