Wire Accessories To Expansion Board; Photoelectric Sensors And Edge Sensors; Control Station - Chamberlain Elite CSW200501UL Installation Manual

Commercial high-traffic ac swing gate operator
Table of Contents

Advertisement

WIRE ACCESSORIES TO EXPANSION BOARD

Photoelectric Sensors and Edge Sensors

The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection devices are
required prior to gate movement. Monitored entrapment protection devices should have been installed with the operator at the time of installation. Only
ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the operator so the operator is aware of the device. If
the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction.
TERMINALS
EYE ONLY and COM
Open or Close Direction Photoelectric Sensors, the functionality is
based on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is
sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction
is sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is
sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction
is sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is
sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction
is sensed

Control Station

TERMINALS
SBC and COM
Gate command sequence - Open, Stop, Close, Stop, ...
l
Soft Open, Soft Close, Soft Stop (maintained switch does not
l
override external safeties and does not reset alarm condition)
OPEN and COM
Open command - opens a closed gate
l
Soft open (maintained switch does not override external safeties
l
and does not reset alarm condition)
If maintained, pauses Timer-to-Close at OPEN limit
l
Opens a closing gate and holds open an open gate
l
CLOSE and COM
Close command - closes an open gate
l
Soft close (maintained switch does not override external safeties
l
and does not reset alarm condition)
STOP and COM
Stop command - stops a moving gate
l
If maintained, pauses Timer-to-Close at OPEN limit
l
Overrides an Open or Close command
l
FUNCTION
FUNCTION
33
WIRING EXAMPLE
WIRING EXAMPLE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite seriesElite csw200ulElite csw200101ul

Table of Contents