Auxiliary Relay 1 and 2

Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5
Amps) power sources only. Function of relay contact activation determined by switch settings.
SWITCH SETTINGS
AUX RELAY
SETTING
1
Off (no feature
OFF
selected)
Open Limit Switch
OFF
Close Limit Switch
OFF
Gate Motion
OFF
Pre-Motion Delay
ON
Power
ON
Tamper
ON
Cycle Quantity
ON
Feedback*
* Cycle count
First, note the current Aux Relay switch positions. To determine the
actual cycles that the gate operator has run (in thousands), set all three
Aux Relay switches to the ON setting for Aux Relay 1. The Expansion
Board's 1, 2, and 3 LEDs will blink out the cycle count, with 1 LED
blinking 1000's, 2 LED blinking 10,000's, 3 LED blinking 100,000's, and
simultaneously all three LED's blink 1,000,000's (e.g. 1 LED blinks 3
times, 2 LED blinks 6 times, and 3 LED blinks once. Cycle count is
163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles.
After servicing, set Aux Relay switches back to their appropriate
positions. Cycle count cannot be reset or changed. If under 1,000 cycles
the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off.
NOTE: The expansion board will flash the cycle count 3 times then all the
LEDs will turn on solid for 10 seconds then turn off.
Auxiliary relay wiring example
EXPANSION BOARD OVERVIEW
2
3
OFF
OFF
Relay always off.
Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier
OFF
ON
gate).
Energizes when not at close limit. For an additional audible or visual display, connect an external light (low
ON
OFF
voltage).
Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an
ON
ON
external buzzer or light (low voltage).
Energizes 3 seconds before gate motion and
remains energized during gate motion. The onboard
OFF
OFF
alarm will sound. For an additional audible or visual
display, connect an external buzzer or light (low
voltage).
ON
OFF
Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible or
OFF
ON
visual display, connect an external buzzer or light (low voltage).
The 1, 2, and 3 LEDs will blink out the cycle count
ON
ON
(cycle count is stored on the control board). See
below.
AUX RELAY 1
Not used.
Red light wired to AUX RELAY 1. Green light wired to AUX RELAY 2.
GATE STATE
Closed
Opening
Open
Closing
Defined Mid Stop
Undefined Mid Stop
Timer more than 5
seconds
Timer less than 5
seconds
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON
32
AUX RELAY 2
Energizes 3 seconds before gate motion and
remains energized during gate motion. For an
additional audible or visual display, connect an
external buzzer or light (low voltage).
Red/green light functionality, see below.
RED/GREEN LIGHT FUNCTIONALITY
AUX RELAY 1 SWITCHES
1 OFF
2 OFF
3 OFF
Red light OFF*
Red light ON/Flash
Red light OFF
Red light ON/Flash
n/a
Red light ON
Red light OFF
Red light ON/Flash
AUX RELAY 2
SWITCHES
1 ON
2 ON
3 ON
Green light OFF
Green light OFF
Green light ON
Green light OFF
n/a
Green light OFF
Green light ON
Green light OFF