Fine Tune The Force; Obstruction Test - Chamberlain Elite CSW200501UL Installation Manual

Commercial high-traffic ac swing gate operator
Table of Contents

Advertisement

Readjust the Limits
To readjust the limits, follow the "Set the Limits" and "Set the Force and Run Distance" instructions above. It is important that the force and run distance
are set after every limit readjustment.

Fine Tune the Force

Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is
used for fine tuning the force where wind or environmental changes may affect the gate
travel. The REVERSAL FORCE DIAL is set to minimum at the factory.
Based on the length and weight of the gate it may be necessary to make additional force
adjustments. The force setting should be high enough that the gate will not reverse by itself
nor cause nuisance interruptions, but low enough to prevent serious injury to a person.
The force setting is the same for both the open and close gate directions.
Settings 1-3: Fixed force settings (the force will not adjust due to gate wear or temperature
changes)
Settings 4-10: Automatically increase the force due to gate wear or temperature changes
1. Open and close the gate with the TEST BUTTONS.
2. If the gate stops or reverses before reaching the fully open or closed position, increase
the force by turning the force control slightly clockwise.
3. Perform the "Obstruction Test" after every limit and force setting adjustment (see
below).

Obstruction Test

The operator is equipped with an inherent (built in to the operator) obstruction sensing device. If the gate encounters an obstruction during motion, the
operator will reverse direction of the gate and then stop. The following procedure will test ONLY the inherent (built in to the operator) obstruction sensing
device:
1. Open and close the gate with the TEST BUTTONS, ensuring that the gate is stopping at the proper open and close limit positions.
2. Place an object between the open gate and a rigid structure. Make sure that any external entrapment protection devices will NOT be activated by the
object.
3. Run the gate in the close direction. The gate should stop and reverse upon contact with the object. If the gate does not reverse off the object, reduce the
force setting by turning the force control slightly counter-clockwise. The gate should have enough force to reach both the open and close limits, but
MUST reverse after contact with an object.
4. Repeat the test for the open direction.
Test the operator after any adjustments are made.