Technical Specifications

This section provides important technical specifications related to the device.
CONTENTS
Section 5.1, "Power Supply Specifications"
Section 5.2, "PoE Output Specifications"
Section 5.3, "Failsafe Alarm Relay Specifications"
Section 5.4, "Copper Ethernet Port Specifications"
Section 5.5, "Fiber Optic Ethernet Port Specifications"
Section 5.6, "Operating Environment"
Section 5.7, "Mechanical Specifications"
Section 5.8, "Dimension Drawings"
Section 5.1

Power Supply Specifications

Power
Minimum Input
Supply Type
54 VDC
a
(T) denotes time-delay fuse
Section 5.2

PoE Output Specifications

The RUGGEDCOM RS900GP adheres to the following power output and IEEE 802.3 specifications depending on
the input voltage supplied to the device.
Power Supply Specifications
Maximum Input
45 VDC
57 VDC
Power In
51 to 57 VDC
45 to 57 VDC
Fuse Rating
Isolation
a
6.3A (T)
1.5 kVDC
50 to 57 VDC, 30 W per Port Maximum (IEEE 302.at)
44 to 57 VDC, 15 W per Port Maximum (IEEE 302.af)
Technical Specifications
Maximum
Maximum Power
Combined
Consumption
Power Output
at PoE Ports
15 W
273 W
Power Out
Chapter 5
23