Siemens SIMATIC NET RUGGEDCOM RS910L Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS910L:

Advertisement

Quick Links

Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM RS910L
Edition
02/2020
https://www.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RS910L

  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS910L Edition 02/2020 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS910L Communication Ports Technical Specifications Installation Manual Certification 02/2020 C79000-G8976-1030-06...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommend- ed or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Disclaimer of Liability ......................v Registered Trademarks ......................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................
  • Page 5 Table of Contents Power Supply Specifications ................29 Failsafe Alarm Relay Specifications ..............30 Supported Networking Standards ................ 30 Copper Ethernet Port Specifications ..............30 Fiber Optic Ethernet Port Specifications ............... 31 Serial Port Specifications ..................32 Operating Environment ..................32 Mechanical Specifications ..................
  • Page 6: Preface

    However, deviations between the product and the documentation may exist. Siemens shall not be liable for any errors or omissions contained herein or for conse- quential damages in connection with the furnishing, performance, or use of this ma- terial.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7 Telephone Toll-free: 1 888 264 0006 Tel: +1 905 856 5288 Fax: +1 905 856 1995 E-Mail ruggedcom.info.i-ia@siemens.com https://www.siemens.com RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RS910L is a utility-grade serial device server and managed Ether- net switch supporting Ethernet over VDSL (EoVDSL). The RUGGEDCOM RS910L can be configured with two serial ports (RS485/RS422/RS232) and/or two Ethernet ports (copper of fiber). The RUGGEDCOM RS910L can interconnect multiple types of intelligent electronic de- vices (IEDs) that have different methods of communication.
  • Page 11: Description

    Introduction 1.2 Description Ethernet Over VDSL (EoVDSL) • 2 x Ethernet over VDSL (EoVDSL) ports • Up to 5 km (3.1 mi) LAN segments • Symmetric data rates up to 35 Mbps • Asymmetric data rates up to 40 Mbps • Automatically selects fastest data rate based on distance and quality of cable •...
  • Page 12 Introduction 1.2 Description POWER LED ALARM LED [Optional] Copper (10/100Base-TX) or Fiber Optic (100Base-FX) Ethernet Ports EoVDSL Port Serial Ports RS232 Console Port (Serial) Failsafe Alarm Relay Chassis Ground Connection Power Supply Terminal Block Figure 1.1 RUGGEDCOM RS910L POWER LED Illuminates green when power is supplied to the device. ALARM LED Illuminates red when an alarm condition exists.
  • Page 13: Required Tools And Materials

    Siemens also does not recommend using copper Ethernet ports to interface with de- vices in the field across distances that could produce high levels of ground potential rise (i.e.
  • Page 14: Supported Fiber Optic Cables

    Introduction 1.5.1 Supported Fiber Optic Cables 1.5.1 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions. Cable Type Wavelength (nm) Modal Band- Distance (m) width (MHz·km) 100Base-FX 1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 —...
  • Page 15 Introduction 1.5.1 Supported Fiber Optic Cables RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: Installing The Device In Hazardous Locations

    2.2 Installing the Device in Hazardous Locations Verify all items are included. NOTICE If any item is missing or damaged, contact Siemens for assistance. Installing the Device in Hazardous Locations The RUGGEDCOM RS910L is designed to comply with the safety standards for Class I, Division 2 hazardous locations where concentrations of flammable gases, vapors or liquids may be present, as opposed to normal operating environments.
  • Page 18: Mounting The Device

    Installing the Device 2.3 Mounting the Device Mounting the Device The RUGGEDCOM RS910L is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be attached to a DIN rail or panel. IMPORTANT Heat generated by the device is channeled outwards from the enclosure. As such, it is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some convectional airflow.
  • Page 19 Installing the Device 2.3.1 Mounting the Device on a DIN Rail Mounting the Device To mount the device to a DIN rail, do the following: Hook the top teeth of the adapter onto the DIN rail. Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver.
  • Page 20: Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel Removing the Device To remove the device from a DIN rail, do the following: Insert a flathead screwdriver into the slot of the sliding release and move it down. DIN Rail DIN Rail Adapter Figure 2.2 Removing the Device from a DIN Rail...
  • Page 21: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay Place the device against the panel and align the adapters with the mounting holes. Screw Panel Mount Adapter Figure 2.3 Panel Mounting Secure the adapters to the panel with #6-32 screws. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 22: Connecting Power

    Installing the Device 2.5 Connecting Power Connect a failsafe device to the terminal block. Normally Closed Common Normally Open Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RS910L supports power input from a single high AC/DC or low DC power supply. IMPORTANT •...
  • Page 23: 2.5.1 Connecting High Ac/Dc Power

    Installing the Device 2.5.1 Connecting High AC/DC Power 2.5.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: NOTICE Electrical hazard – risk of damage to equipment Do not connect AC power cables to terminals for DC power. Damage to the power supply may occur.
  • Page 24 Installing the Device 2.5.1 Connecting High AC/DC Power Connect the positive wire from the power source to the positive/live (+/L) termi- nal on the terminal block. Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal Surge Ground Terminal Braided Ground Cable Figure 2.5 Terminal Block Wiring RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 25: 2.5.2 Connecting Low Dc Power

    Installing the Device 2.5.2 Connecting Low DC Power ± ± ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.6 Terminal Block Wiring – Dual DC Power Supply Inputs Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
  • Page 26 Installing the Device 2.5.2 Connecting Low DC Power Connect the positive wire from the power source to the positive terminal on the terminal block. ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.7 Terminal Block Wiring – Single DC Power Supply Inputs Connect the negative wire from the power source to the negative terminal on the terminal block.
  • Page 27 Installing the Device 2.5.2 Connecting Low DC Power [Optional] If a redundant connection is required, repeat Step 2 Step 3 connect the secondary power inputs. ± ± ± ± Positive Terminal Negative Terminal Surge Ground Terminal Braided Ground Cable Figure 2.8 Terminal Block Wiring – Dual DC Power Supply Inputs Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS910L console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS910L User Guide for the RUGGEDCOM RS910L.
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The following is the pin-out for the port:   Name Description Reserved (Do Not Connect) Transmit Data Receive Data Reserved (Do Not Connect) Signal Ground Reserved (Do Not Connect) Reserved (Do Not Connect)
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM RS910L can be equipped with various types of communication ports to enhance its abilities and performance. Ports 1 and 2 Ports 3 and 4 Port 9 Figure 4.1 Port Assignment Port Type 1 and 2 Serial Ports 3 and 4 Copper (10/100Base-TX) or Fiber Optic (100Base-FX) Ethernet Ports EoVDSL Port...
  • Page 31 Communication Ports 4.1 Copper Ethernet Ports WARNING Electric shock hazard – risk of serious personal injury and/or equipment inter- ference When shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more importantly, create a potential shock hazard that can result in serious injury.
  • Page 32: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Reg- istered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors. Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link.
  • Page 33 Master and pushed to the Slave. Data flowing from the Master to the Slave is designated downstream, while data flowing from the Slave to the Master is designated upstream. Siemens supports two types of EoVDSL: • Universal EoVDSL Universal EoVDSL ports are Master/Slave selectable and offer symmetric data rates (upstream and downstream) up to 35 Mbps.
  • Page 34: 4.3.1 Eovdsl Wiring

    Communication Ports 4.3.1 EoVDSL Wiring Pin-Out The following is the pin-out for the RJ11 connectors: Note All RJ11 connectors conform to the standard telephony pin configuration.   Description Reserved (Do Not Connect) Reserved (Do Not Connect) Ring Figure 4.8 EoVDSL RJ11 Modem Port Reserved (Do Not Connect) Reserved (Do...
  • Page 35: 4.3.2 Configuration And Setup

    Communication Ports 4.3.2 Configuration and Setup 4.3.2 Configuration and Setup If the RUGGEDCOM RS910L and another device both have Universal EoVDSL ports, configure one device to be the Master and the other the Slave. If both devices have a Long-Reach EoVDSL port, no Master/Slave configuration is necessary, since the ports will already be fixed as Master or Slave.
  • Page 36 Communication Ports 4.3.3 EoVDSL Performance Note Assuming the distance can support the speed setting, the time to establish a link is typically 15 to 30 seconds. Universal EoVDSL Performance Characteristics On No. 24 AWG Polyethylene Insulated Cable (PIC) twisted-pair wiring, the following performance is typical with Universal EoVDSL: Distance Downstream/Upstream (Mbps)
  • Page 37 Communication Ports 4.3.3 EoVDSL Performance RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 38: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the pow- er supply is provided at the power source. Hazardous Environments Power Sup- Input Range Internal Isolation...
  • Page 39: Failsafe Alarm Relay Specifications

    Technical Specifications 5.2 Failsafe Alarm Relay Specifications Failsafe Alarm Relay Specifications Hazardous Environments Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 1500 V for 1 minute 80 VDC 0.3 A 30 VAC Non-Hazardous Environment Maximum Switching Voltage Rated Switch- Isolation ing Current 30 VDC 2 A, 60 W...
  • Page 40: Fiber Optic Ethernet Port Specifications

    3 dBm. To convert from peak to average, subtract 3 dBm. • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. 10Base-FL Fiber Optic...
  • Page 41: Serial Port Specifications

    Technical Specifications 5.6 Serial Port Specifications Tx (dBm) Cable Rx Sen- Rx Satu- Dis- Power Connec- Tx λ Mode Type sitivity ration tance Budget Mini- Maxi- tor Type (nm) (μm) (dBm) (dBm) (km) (dB) 9/125 1300 50/125 1300 -22.5 Typical. Serial Port Specifications The following details the specifications for serial ports that can be ordered with the RUGGEDCOM RS910L.
  • Page 42: Mechanical Specifications

    Technical Specifications 5.8 Mechanical Specifications Mechanical Specifications Weight 1.2 kg (2.7 lbs) Enclosure 20 AWG Galvanized Steel Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. 65.3 116.59 7.87 Figure 5.1 Overall Dimensions RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 43 Technical Specifications 5.9 Dimension Drawings 128.4 13.64 101.6 11.2 78.74 120.65 Figure 5.2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 44: Certification

    Certification The RUGGEDCOM RS910L device has been thoroughly tested to guarantee its confor- mance with recognized standards and has received approval from recognized regula- tory agencies. Approvals This section details the standards to which the RUGGEDCOM RS910L complies. 6.1.1 This device meets the requirements of the following Canadian Standards Association (CSA) standards under certificate 1550963: •...
  • Page 45: 6.1.2 Fcc

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiolog- ical Health 6.1.4 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.5...
  • Page 46: Rohs

    Certification 6.1.6 RoHS 6.1.6 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro- HS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 47 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severi- ty Levels AC Pow- ± 4 kV Line-to-Ground er Ports ± 2 kV Line-to-Line Induced (Conducted) RFI Signal Ports 10 V 61000-4-6 DC Pow- 10 V er Ports AC Pow- 10 V er Ports Earth...
  • Page 48 Certification 6.2 EMC and Environmental Type Tests EMC Immunity Type Tests per IEEE 1613 Note The RUGGEDCOM RS910L meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communica- tion loss, while Class 2 requires error-free and interrupted communications. Description Test Levels Enclosure Contact...
  • Page 49 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM RS910L Installation Manual, 02/2020, C79000-G8976-1030-06...
  • Page 50 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

This manual is also suitable for:

Ruggedcom rs910l

Table of Contents