Communication Ports
WARNING!
Electric shock hazard – risk of serious personal injury and/or equipment interference. If shielded
cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the
RJ45 receptacles at either end. Ground loops can cause excessive noise and interference, but more
importantly, create a potential shock hazard that can result in serious injury.
LEDs
Each port features an LED that indicates its link/activity state.
Figure 11: LED for RJ45 Ports (9 to 10)
1. Link/Activity LED
Figure 12: LED for Micro-D Ports (9 to 10)
1. Link/Activity LED
Pin-Out
The following are the pin-out descriptions for the RJ45 and micro-D connectors:
8
Figure 13: RJ45 Port Pin Configuration
18
1
1
1
1
1
LED
Link/Activity
Green (Solid)
Green (Blinking)
Off
Name
Pin
10/100Base-TX
1
RX+
2
RX-
3
TX+
4
Reserved (Do
Not Connect)
RUGGEDCOM RS900GP
Installation Guide
State
Description
Link established
Link activity
No link detected
Description
1000Base-TX
BI_DB+
Receive Data+ or
Bi-Directional
BI_DB-
Receive Data- or
Bi-Directional
BI_DA+
Transmit Data+
or Bi-Directional
BI_DD+
Bi-Directional
Copper Ethernet Ports