Jaguar Model J-390
JAGUAR J-390 NON-DIRECT VENT, SIDEWALL VENTING
All joints must be liquid and pressure tight. Use 4" dia. PVC/CPVC schedule 40 pipe or U/L listed single wall 4" dia.
Figure 6. Non-direct vent, side wall venting - utilizing PVC/CPVC pipe for venting.
STANDARD
90 ELBOW
AIR INTAKE
(DO NOT BL0CK)
Figure 7. Non-direct vent, side wall venting - utilizing stainless steel vent materials for venting.
** Definition of Snow Line: Knowledge of local conditions will reveal the maximum height that repeated snowfalls accumulate to.
The height should be used as the SNOW LINE.
* AL 29-4C IS A REGISTERED TRADEMARK OF ALLEGHENY LUDLUM CORP.
AL29-4C S.S.*. venting materials (See page 7).
SLOPE UP 1/4 IN.
PER FOOT MIN.
FROM BOILER TO
VENT TERMINATION
4 IN. DIA.
PVC/CVPC
PIPE FOR
VENT
90 ELBOW
AIR INTAKE
(DO NOT BL0CK)
SLOPE UP 1/4 IN.
PER FOOT MIN.
FROM BOILER TO
VENT TERMINATION
4 INCH. DIA.
STAINLESS
STEEL VENTING
MATERIAL FOR
VENT
6" MIN.
10" MAX.
TERMINATION 90 ELBOW
WITH SCREEN
A U/L LISTED FLASHING
AND SEALING BOOT MUST
BE USED ON COMBUSTIBLE
12" MIN
WALLS.
SNOW LINE
(SEE DEFINITION)
OUTSIDE WALL
6" MIN
10" MAX
OUTSIDE VENT TERMINATION
ELBOW WITH SCREEN
WALL THIMBLE MUST BE USED
ON COMBUSTIBLE WALLS
SNOW LINE
(SEE DEFINITION)
OUTSIDE WALL