Slant/Fin INTREPID TRDV-30-0.85 Installation And Operation Instructions Manual

Trdv series direct vent oil-fired water boiler/no. 2 oil
Hide thumbs Also See for INTREPID TRDV-30-0.85:

Advertisement

INTREPID
DIRECT VENT OIL-FIRED WATER BOILER/NO. 2 OIL
READ AND SAVE THESE INSTRUCTIONS FOR REFERENCE
SAFETY WARNING:
KEEP BOILER AREA CLEAR AND FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS
AND LIQUIDS. FAILURE TO ADHERE TO ABOVE SAFETY
WARNING, MAY RESULT IN PERSONAL INJURY OR DEATH
AND PROPERTY DAMAGE.
CONTENTS
Ratings and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-3
Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3
Vent Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3
Vent Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3
Installing Water trim . . . . . . . . . . . . . . . . . . . . . . . . . . . ..3
Piping for Tankless heater . . . . . . . . . . . . . . . . . . . . . . .4
Installing Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Oil Supply Piping . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . .5
. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . .5
Precautions Before Starting . . . . . . . . . . . . . . . . . .. . . . .5
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . .5
Cleaning and Filling New Water Boiler . . . . . . . . . . . . . .5
Wiring Diagrams . . . . . . . . . . . . . . . . . .. . . . . . . . . . . .6-8
Burner Data:
Riello . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .9
Beckett . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Extended Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Freezing Protection . . . . . . . . . . . . . . . . .. . . . . . . . . . .12
Oil Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..12
General Maintenance . . . . . . . . . . . . . . . . .. . . . . . . . .12
Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Appendix B, C & D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
THIS BOILER OPERATES WITH POSITIVE PRESSURE IN THE
FLUE AND OVER FIRE, ALL SEALS MUST BE IN PLACE WHEN
OPERATING THE BOILER. ALL VENTING MUST BE INSTALLED
AND SEALED ACCORDING TO THE VENT MANUFACTURER'S
INSTRUCTIONS.
Heating Contractor
Address
Phone Number
Printed in Canada 03/08-03/08
TRDV Series
INSTALLATION AND OPERATING INSTRUCTIONS
PAGE
IMPORTANT: The installation of this equipment must
conform to the requirements of the authority having
jurisdiction or, in the absence of such requirements, to the
Installation code for oil burning equipment, CSA B139-00, or
the latest edition. The installation must also conform to the
additional requirements in this Slant/Fin Instruction Manual.
Where there is any difference, the more stringent
requirement shall govern
In addition, where required by the authority having
jurisdiction, the installation must conform to American
Society of Mechanical Engineers Safety Code for Controls
and Safety Devices for Automatically Fired Boilers, No.
CSD-1, latest edition.
Do not use gasoline crankcase drainings or any oil
containing gasoline.
Never burn garbage or paper in this unit, and never leave
combustible material around it.
Boiler Model Number
Boiler Serial Number
Installation Date
3131567
CONFORMS TO UL STD 726
CERTIFIED TO CAN/CSA STD
B140.7-05
Publication No. TRDV-40
Revision B

Advertisement

Table of Contents
loading

Summary of Contents for Slant/Fin INTREPID TRDV-30-0.85

  • Page 1: Table Of Contents

    The installation must also conform to the Care and Maintenance: additional requirements in this Slant/Fin Instruction Manual. Extended Shutdown ......12...
  • Page 2: Ratings And Dimensions

    † Ratings apply to the use of light oil at 11 000 W/L (140,000 Btu per gallon) and apply only with Slant/Fin supplied burners properly adjusted...
  • Page 3: Clearances

    OFFS MUST BE PIPED TO SAFE PLACE FOR pipe and prevent it from sagging. DISCHARGE,ACCORDING TO LOCAL CODE OR THE C. Maximum wall thickness is 356mm (14”). Contact Slant/Fin AUTHORITY HAVING JURISDICTION. for recommendations in case of thicker wall. D. Gases will form white plume in winter. Plume could PIPING obstruct window view.
  • Page 4: Piping For Tankless Heater

    INTREPID TRDV PIPING FOR WATER UNITS VOLUME OF WATER IN STANDARD PIPE OR TUBE I. CIRCULATING SYSTEM A. FORCED CIRCULATION hot water heating system: Use the top Standard Steel Pipe Copper Pipe tapping as supply tapping, and use the front and/or rear Nominal bottom tappings for the return.
  • Page 5: Oil Supply Piping

    1. Proportions: .25kg (1 lb.) of either chemical per 189L burner on the supply (and return if two pipe) to facilitate (50 gallons) of system water. servicing. See Slant/Fin publication on one-pipe and two-pipe 2. Stir chemical in water until dissolved and pour into fuel oil systems.
  • Page 6: Wiring Diagrams

    INTREPID TRDV BLOCKED VENT SAFETY SWITCH AND OTHER SAFETY CONTROLS...
  • Page 7 INTREPID TRDV...
  • Page 8 INTREPID TRDV 15 AMP . MAXIMUM OVERCURRENT PROTECTION BLOCKED VENT SAFETY SWITCH AND OTHER SAFETY CONTROLS...
  • Page 9: Riello

    INTREPID TRDV RIELLO BURNER DATA — BURNER MODEL BF-5 Riello Firing Rate No. 2 Oil Nozzles Oil Pump Approx. "A" Boiler Model Burner Pressure Air Band Size Angle & Turbulator Mfg. Setting Opening Model L/Hr L/Hr (GPH) type TRDV-30-0.85 BF-5 3.21 0.85 2.46...
  • Page 10 INTREPID TRDV SETTING THE AIR DAMPER ADJUSTMENT (see figure 10 & picture 2) 1. The initial air damper setting is made by turning screw (2) until the top edge of the air damper (3) is aligned with the number according to the burner setup chart. 2.
  • Page 11: Beckett

    Flush with #3005855 insulation (S/F Part to a #430161) 75 mm maximum 75 mm (2-15/16”) (2-15/16”) recess of Slant/Fin no more Figure 11 burner than 6mm collar Part (1/4") #430010 170 mm (6-11/16”) Figure 14 6 mm (1/4”) MINIMUM 329 mm (12-15/16”)
  • Page 12: Care And Maintenance

    INTREPID TRDV burner data pages for the burner installed.) Replace oil CARE AND MAINTENANCE nozzle with new one and readjust electrodes. To insure proper burner operation ONLY THE NOZZLES SPECIFIED CAUTION: DO NOT ATTEMPT TO START THE BURNER IN THIS MANUAL OR ON THE BURNER LABEL SHOULD WHEN EXCESS OIL HAS ACCUMULATED, WHEN THE UNIT BE USED FOR REPLACEMENT.
  • Page 13: Iv. General Maintenance

    INTREPID TRDV IV. GENERAL MAINTENANCE F. WATER SYSTEM: check These operations are recommended to be performed at 1. System to be full of water and pressure to remain regular intervals: stable (between 83 kPa (12 psi) and 172 kPa (25 A.
  • Page 14: Appendix B, C & D

    Use of non-oxygen diffusion barrier underfloor tubing The boiler warranty does not cover leaks resulting from with a heat exchanger, Slant/Fin recommends the use of corrosion caused by the use of underfloor plastic tubing underfloor plastic tubing with an oxygen diffusion barrier.
  • Page 15 INTREPID TRDV...
  • Page 16 ©Slant/Fin Corp. 1996. Printed in Canada 03/08. Publication TRDV-40 SLANT/FIN LTD/LTEE, 6450 Northam Drive, Mississauga, Ontario L4V 1H9 • Phone: (905) 677-8400 / FAX: (905) 677-1829 / Order Desk Fax: (905) 677-9015 www.slantfin.ca / E-mail: orderdesk@slantfin.ca / info@slantfin.ca...

Table of Contents