rEMOvE ELEcTric HEaTinG ELEMEnT
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove service panel (See page 4-16).
2.
Remove 6 wire connectors from high temp
thermostat, high temp cutout and heater
coil.
3.
Remove the 1/4" hex head screw that
secures bracket to bottom of dryer.
4.
5.
1/4" Hex
Head Screw
4-44
Lift bracket and heater assembly to remove
the bottom edge of the assembly and press
down to release the tab from inside the heat
plenum at the back of the dryer.
Remove assembly from the dryer.
Locking