HEATING ELEMENT AND RELATED COMPONENTS
~-
ELECTRIC
MODELS
Jumper
WII'lI
H.atar
CoM~
-~
I'
I
\
HIgh LImIt
~.}
Thermoetat
Upper
CoRa
HEAT CONE
1. Remove front panel.
'2. Remove screws holding heater cone
\,
shield to base. Remove shield from
dryer.
3. Remove screw in front of cone
holding cone to base and remove
ED/GD401 1090
screw in back of cone holding cone
tab to inlet air duct.
4. Remove wires to terminal posts.
5. Pull cone out of dryer.
SECTION 3. SERVICE PROCEDURES
3-31