rEMOvE ccu MOunTinG BrackET
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Open dryer top (See page 4-3).
2.
Remove the 1/4" hex head screw from each
end of bracket.
Step-down
Transformer
3.
Set bracket on the top of the drum.
4.
On Model 22 dryers, remove the UIC
transformer and the step-down transformer.
(See page 4-8).
5.
On Model 25 dryers, there is no step-down
transformer. Remove the UIC transformer
(See page 4-8).
Two 1/4"
Hex Head
Screws
6.
Remove the CCU (See page 4-9).
4-7
UIC
Transformer