Kohler VIA Series Installation Instructions Manual page 20

Vitreous china wall-hung p-trap toilet
Table of Contents

Advertisement

3. K-23056T/K-23056TW installation
3. K-23056T/K-23056TW
1) Transformer Installation
Fix the transformer onto the wall, as illustrated, the
output connector of transformer(with 2 core female
connector) through the tube(suggestion: tube inner dia.
16~ 20) into tank. Connect the input terminal of
transformer(black) with power supply 220V/110V AC.
Customer can use the PVC pipe for wiring.
Warning:
Don't mistake the input and output
terminal, or it may cause damage to the product.
Insulation measures must be taken at the
connection. Otherwise, short-circuit current may
occur and damage the transformer.
1)
( 2
)
(
) AC220V/110V
2) Faceplate Installation
A. When tighten four locknuts on support board, adjust
to "OPEN" mark as shown.
B. Tighten four screws to "LOCK" mark after installing
support board as shown.
2)
A.
"OPEN"
B.
1288805-T01-B
(
16~ 20)
"LOCK"
Low-voltage AC
Ceiling
Transformer Output
Connector (In Tank)
(
)
Supporting Board
-15-
Brushing Pipe
Input AC 220V/110V (Black)
AC220V/110V ( )
Output AC 6V
AC6V
Transformer Assy.
Locknut
Fixing Lock
Supporting Board
Locknut